1. Product Introduction
The structure of the plasma cleaning machine is mainly divided into three major parts, namely the control unit, radio frequency power supply and plasma generator.
Features: Atmospheric pressure plasma cleaning equipment with the same processing effect as vacuum plasma cleaning machine. A high-performance surface treatment technology, atmospheric pressure glow plasma technology, in addition to being able to reproduce the quality of vacuum plasma in atmospheric pressure, it can also generate more high-energy free radicals than vacuum plasma and can perform surface treatment more quickly.
Advantages:
1. Good processing effect, the same processing effect as vacuum plasma cleaning machine
2. Fast efficiency, the argon plasma cleaning machine emits light for the entire light strip, no need for plasma head movement
3. Low temperature, baseband temperature is less than 40°
4 , Wide width can be customized according to customer needs, 0-3 meters
5, good processing uniformity
6, compact structure, easy to connect with customer pipeline and graft to customer pipeline
7, plasma power supply voltage is low, without damaging the product
Second, the machine configuration
Machine configuration |
model |
CON50-AR |
CON80-AR |
Way of working |
Atmospheric linear light output |
power |
750W |
1000W |
Processing range |
500mm |
800mm |
Processing height |
0-6mm, the closer the flame is to the product, the better the effect |
Equipment size |
1500*1200*1300mm |
1500*1500*1300mm |
weight |
260KG |
Input power |
220V, 50HZ |
frequency |
13.56MHZ |
Working gas |
Argon+Oxygen |
3. Application areas
Flat glass screen:
Printing and packaging industry:
Polymer film
|

Protective film |
Spray printing
Before spray coating
|

Before printing on plastic plates |
4. Installation Instructions
1. The ambient temperature is required to be between 15 and 35 ℃, and air conditioning is required;
2. An oil-free air compressor is required on site. It is recommended to match the power of 2.2KW, the nominal volume flow of 200 L/min, and the
rated discharge pressure: 0.7MPA
3 . Humidity requirement is 40% ~ 80%, no condensation, dehumidifier should be installed;
4. Power grid requirements: AC220V, 50Hz;
5. Power grid fluctuations: ± 5%, grid ground meets international requirements. In areas where the voltage amplitude is more than 5%, automatic voltage stabilization and current stabilization devices should be installed;
6. There should be no strong electromagnetic signal interference near the installation equipment, and there should be no radio transmitting station (or relay station) around the installation site;
7. Ground amplitude: less than 50um; vibration acceleration: less than 0.05g; avoid a large number of stamping and other machine tools nearby;
8. Equipment space requirements to ensure smoke-free and dust-free, avoid metal dusting and other serious working environment;
9. Air pressure: 0.4 ~ 0.7Mpa;
10. In some environments, anti-static floor should be installed to strengthen the shield, etc.;